Single punching machine installation and wiring
Disposable Plastic Surgical Use Forceps/Tweezers/Clips/Pincers Forceps&Tweezers Luck Medical Consumables Co.,LIMITED , https://www.luckmedical.com
1. The single punching machine should be installed on a firm work surface and fixed with four M10 anchor bolts. The height from the work surface to the ground is about 600 mm (the ease of hand operation). In order to facilitate the disassembly and repair, the position of the corresponding punching rod on the workbench should have a hole of about 35 mm in diameter.
2. The machine should have a reliable grounding wire to ensure safe use.
3. After turning on the power, turn on the motor and observe the running direction of the motor. It is consistent with the arrow on the protective cover. If it is inconsistent, adjust the wiring.
Second, single punching machine die installation and tablet adjustment
1, the installation of the die
1) Install the lower Panasonic shackle fixing bolt, turn the handwheel to raise the lower punching rod to the high position of the zui, insert the undershoot into the hole of the lower punching rod, and pay attention to the slanting of the lower punching rod. Bolt, and insert it to the end, then tighten the lower punch fixing bolt.
2) Install the upper loosening and tightening nut, insert the upper punch into the hole of the upper punching rod, insert it into the bottom and tighten the nut.
3) Install the middle mold loose loose mold fixing bolt, put the middle mold vertically into the hole of the platen, and then tighten the fixing bolt after it is in place.
4) Turn the handwheel by hand to slowly lower the upper punch into the middle die hole to observe whether there is collision or friction. If there is collision or friction, loosen the middle die plate fixing bolts (two) and adjust the middle die table. The plate is fixed in position so that the upper punch smoothly enters the middle die hole, and then the middle die plate fixing nut is tightened.
2. Adjust the output of the film and turn the handwheel to raise the lower punch to the high position of the Zui. If the lower punch surface is aligned with the plane of the middle die, loosen the fixing bolts, loosen the platen and adjust the gear to make the lower punch surface. Align with the plane of the middle mold, then still install the pressure plate, and then tighten the fixing bolts. At this point, shake the handwheel by hand and press it if everything is normal.
3, the adjustment of the filling depth (ie the adjustment of the weight of the tablet)
Loosen the fixing bolts and loosen the adjusting wheel pressure plate. Rotate the lower adjustment wheel to the right to rotate, the piece weight increases; to the left, the piece weight decreases. After adjustment, install the pressure plate and fixing bolts.
4, the adjustment of the pressure (that is, the adjustment of the hardness of the tablet)
Loosen the connecting rod lock nut and rotate the connecting rod, rotate to the left to move the upper punching rod downward, the pressure will increase, and the hardness of the pressed tablet will increase; otherwise, the pressure will decrease, the hardness of the tablet will decrease, and the hardness will be adjusted. The lock nut should be tightened.