The reason why the pressure washer is not unstable or the pressure is unstable
Why is there no pressure or unstable pressure in the high pressure cleaner? And what should I do? The following will be explained in detail by Shanghai Bayu technical staff, welcome to browse! First, the pressure washer is unstable after starting, or sometimes there is no 1, high-pressure water pump or water pipe inhale the air, then we just need to pull the trigger water cannons, work pressure and lower pressure washer running for a while, until a stable pressure so far.  2 , the water supply is insufficient, then check the pressure of the water source is sufficient, and some high-pressure cleaners do not have self-priming function, then add a booster pump to solve the problem.  3 , the water supply filter is blocked, then just clean the water supply filter. Second, the high pressure cleaner can not reach the rated pressure of the equipment  When the high pressure cleaner is running, there is a certain working pressure that does not reach the rated pressure of the equipment, or the pressure only stays within a certain range and cannot rise . In this case, first check whether the diameter of the high pressure nozzle matches, if not Match the replacement high pressure nozzle. Next check if the pressure regulator is adjusted to the correct position. If the pressure is still not removed under the exclusion of these two conditions, finally check whether the high pressure pump inner seal assembly ( O -ring, water seal) is intact and the piston is damaged. If the piston is damaged, it will need to be repaired.  Third, the pressure of the high pressure cleaner after a certain period of normal operation  1, to check whether the high-pressure nozzle severe wear, such wear is more serious to replace high-pressure nozzles. The high-pressure nozzle of the small pressure equipment is basically free of wear, because the high-pressure nozzles we have equipped are basically heat-treated, but it is difficult to guarantee the high-pressure nozzle of the large pressure equipment.  2, inlet check the filter for clogging, such as a water filter clogging, the filter was washed with water to remove it. If the unclean water source causes the filter to become clogged, increase the external filter or replace the clean water source.  3, were examined regulator, relief valve and internal high pressure water pump seal assembly, such as: pressure regulator and relief of the O-ring wear, and whether the spring seat surface wear, the inside of the pump O-rings Wear, water seal damage, check valve wear or foreign matter. Dental Nitrile Gloves,Nitrile Gloves Large,Eu Medical Dental Gloves,Gloves Nitrile Disposable Gloves Puyang Linshi Medical Supplies Co., Ltd. , https://www.linshimedical.com