How to improve the sterilization result of the electric steam dual-purpose sterilization pot?

In order to obtain good sterilization results, the sterilization pot needs to be connected to the (saturated steam feeder) to spray the high-temperature sterilization kettle, and the sterilization pot is supplied with steam throughout the heating and heat preservation process. The sterilizer can ensure the steam flow in the pot throughout the sterilization process, and the temperature is balanced (the temperature required for sterilization). The temperature in the sterilizer does not increase or fall during the whole process, creating a new steam sterilization without dead angle. concept. Saturated steam sterilization is a new practical technology for sterilization. It is a necessary sterilization equipment for canned products, vacuum body packaging products, glass bottle packaging products, especially plant packaging products. We can guarantee the appearance of the product to a large extent, color vacuum soft packaging sterilization pot, taste, nutrients.
Electric steam dual-purpose sterilization pot Note: completely remove the air inside the pot, so that all the water in the pot is water vapor, sterilization can be thorough. There are several different practices for autoclaving and deflation, but the purpose is to remove the air and evenly heat up the pot to ensure complete sterilization. The common method is to close the bleed valve. After the power is turned on, when the pressure rises to 0.05 MPa, open the vent valve and release the air. After the pressure gauge pointer returns to zero, close the bleed valve. When the valve is re-energized, when the pressure gauge rises to 0.1 MPa, the timing is started, and the pressure is maintained at 0.1 to 0.15 MPa for 20 minutes.
After the electric steam dual-purpose sterilization pot reaches the holding pressure time, the power can be cut off. When the pressure drops to 0.5 MPa, the steam can be slowly released. Care should be taken not to make the pressure drop too fast, causing intense decompression boiling and making the container The liquid overflows. When the pressure drops to zero, the lid can be opened, the medium removed, and placed on the platform for condensation. Do not deflate for a long time, causing changes in the composition of the medium, so that the medium can not be inclined. Once placed for too long, the cover cannot be opened due to the negative pressure inside the boiler. As long as the bleed valve is opened, the atmospheric pressure is entered, the internal and external pressures are balanced, and the cover is easy to open.
Electric steam dual-purpose sterilization pot operation steps:
1. First remove the inner layer sterilization barrel, and then add an appropriate amount of water to the outer layer pot to make the water surface and the triangle shelf level.
2. Put back the sterilization bucket and load the items to be sterilized. Be careful not to pack too much, so as not to hinder the circulation of steam and affect the sterilization effect. Do not contact the barrel end of the flask and the end of the tube to prevent the condensate from drenching the paper at the mouth and penetrating into the tampon.
3. Cap and insert the exhaust hose of the cover into the exhaust groove of the inner sterilization tank. Then tighten the two bolts at the same time in a symmetrical manner to make the bolts tight and not leaking.
4. Heat with an electric furnace or gas, and open the exhaust valve at the same time to boil the water to remove the cold air from the pot. After the cold air is completely drained, close the exhaust valve so that the temperature inside the pot gradually increases as the steam pressure increases. When the pressure in the pot rises to the desired pressure, the heat source is controlled to maintain the pressure for the required time.
Strictly follow the above method to operate the electric steam dual-purpose sterilization pot, which can greatly improve the sterilization effect, and hope to help the new and old users.