Model NO.: HNT-2000
Medical Devices Reg./Record No.: Gsyjxzz20123540587
Mattress to Radiant Box: 81 Cm
Environment Relative Humidity: 30%~75%
Temperature Control Mode: Pre-Heat\Auto and Manual
Mattress Tray Size: 68cm×56cm
Certificate: CE, ISO
Warranty: 12months
Trademark: Healicom
Transport Package: Carton
Specification: CE, ISO
Origin: Jiangsu, China
HS Code: 9018909090
Model NO.: HNT-2000
Medical Devices Reg./Record No.: Gsyjxzz20123540587
Mattress to Radiant Box: 81 Cm
Environment Relative Humidity: 30%~75%
Temperature Control Mode: Pre-Heat\Auto and Manual
Mattress Tray Size: 68cm×56cm
Certificate: CE, ISO
Warranty: 12months
Trademark: Healicom
Transport Package: Carton
Specification: CE, ISO
Origin: Jiangsu, China
HS Code: 9018909090
STANDARD COMPOSITION
1.       Temperature Control Mode: pre-heating control, servo control & manual control;
2.       Instant Parameter Display: set temp, skin temp, heat power rate;
3.       Built-in APGAR Timer and >37°C preset function
4.       Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
5.       Tilting Bed with Rotary Radiant Head;
6.       X-ray Cassette Tray under infant bed, examination light of high illuminance;
7.       Use anti-blast quartz infrared tube as radiant heating source.
TECHNICAL SPECIFICATION
Power |
AC 110 / 220 V, 50Hz / 60Hz |
Input Power |
≤1000VA |
Temperature control range and relative specification |
Control mode |
Pre-warm mode, manual mode, baby mode |
Temperature control range |
25°C~37°C for set temperature ≤37°C |
37°C~38°C, for set temperature >37°C |
Skin temperature sensor measure range |
20°C~42°C |
Deviation between sensor measure temperature and control temperature |
≤0.5°C |
Skin Sensor Precision |
≤0.3°C |
Bed surface temperature Uniformity |
≤1°C |
Temperature Rise Time |
≤45min |
Bed tiltable |
continues adjustable in ±10° |
Alarm |
Sensor failure alarm |
Alarm with audible and visual when sensor open circuit, short circuit or disconnect, cut off power. |
Over temperature alarm |
Alarm with audible and visual when displayed temperature was approach 38°C for set temperature ≤37°C, or approach 39°C for set temperature >37°C, cut off power. |
Deviation alarm |
After temperature equilibrium, alarm with audible and visual when displayed temperature was 1°C above or below control temperature, cut off power if above 1°C. |
Power failure alarm |
Alarm with audible and visual when power failure |
APGAR time |
Alarm with audible when run between 50 seconds to 1 minute, 4 minutes 50 seconds to 5 minutes, 9 minutes 50 seconds to 10 minutes. |
Environment Temperature (It is a suggestion that please do not use outside of the allow environment.) |
Operate temperature range |
18°C~30°C |
Store temperature range |
-20°C~+55°C |
Environment Humidity |
Operate humidity range |
30%RH~75%RH |
Store humidity range |
≤93%RH |
Atmospheric pressure |
Transport and Store atmospheric pressure range |
500hPa~1060hPa |
Operate atmospheric pressure range |
700hPa~1060hPa |
Stream velocity |
Ambit environment stream velocity |
≤0.3m/s |
STANDARD COMPOSITION
1.       Temperature Control Mode: pre-heating control, servo control & manual control;
2.       Instant Parameter Display: set temp, skin temp, heat power rate;
3.       Built-in APGAR Timer and >37°C preset function
4.       Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
5.       Tilting Bed with Rotary Radiant Head;
6.       X-ray Cassette Tray under infant bed, examination light of high illuminance;
7.       Use anti-blast quartz infrared tube as radiant heating source.
TECHNICAL SPECIFICATION
Power |
AC 110 / 220 V, 50Hz / 60Hz |
Input Power |
≤1000VA |
Temperature control range and relative specification |
Control mode |
Pre-warm mode, manual mode, baby mode |
Temperature control range |
25°C~37°C for set temperature ≤37°C |
37°C~38°C, for set temperature >37°C |
Skin temperature sensor measure range |
20°C~42°C |
Deviation between sensor measure temperature and control temperature |
≤0.5°C |
Skin Sensor Precision |
≤0.3°C |
Bed surface temperature Uniformity |
≤1°C |
Temperature Rise Time |
≤45min |
Bed tiltable |
continues adjustable in ±10° |
Alarm |
Sensor failure alarm |
Alarm with audible and visual when sensor open circuit, short circuit or disconnect, cut off power. |
Over temperature alarm |
Alarm with audible and visual when displayed temperature was approach 38°C for set temperature ≤37°C, or approach 39°C for set temperature >37°C, cut off power. |
Deviation alarm |
After temperature equilibrium, alarm with audible and visual when displayed temperature was 1°C above or below control temperature, cut off power if above 1°C. |
Power failure alarm |
Alarm with audible and visual when power failure |
APGAR time |
Alarm with audible when run between 50 seconds to 1 minute, 4 minutes 50 seconds to 5 minutes, 9 minutes 50 seconds to 10 minutes. |
Environment Temperature (It is a suggestion that please do not use outside of the allow environment.) |
Operate temperature range |
18°C~30°C |
Store temperature range |
-20°C~+55°C |
Environment Humidity |
Operate humidity range |
30%RH~75%RH |
Store humidity range |
≤93%RH |
Atmospheric pressure |
Transport and Store atmospheric pressure range |
500hPa~1060hPa |
Operate atmospheric pressure range |
700hPa~1060hPa |
Stream velocity |
Ambit environment stream velocity |
≤0.3m/s |
DRIED POLLACK FLAKES
Dried Pollack Flakes,Dried Pollack Nutrition,Dried Pollack Snack,Pollock Dried
Yanji Yongzhen Food Co., Ltd , https://www.yanjiyongzhenfood.com