Maintenance and maintenance of Olympus biological microscope
Take special care when changing lenses to avoid touching the lens surface with your fingers. The lens should be stored in a dry and clean drying dish, and the lens-free glue is moldy and damaged. When the focus is adjusted, the lens part of the object cannot be in contact with the sample. Turn the coarse adjustment knob to make the objective lens as close as possible to the sample (visual measurement), then adjust the coarse adjustment knob while observing it from the eyepiece, so that the objective lens gradually leaves the sample until it is visible. When micro-organizing the image, use the fine-tuning knob to adjust the image to clarity. When there is dirt on the surface of the lens, it is strictly forbidden to rub it by hand or fabric. The surface dust should be blown off with a special rubber ball. When the microscope is not in use, it should be covered with a dust cover (the dust cover can be made of glass, silk cloth, etc.) 2. Do not force the various adjustment devices to cross the limit. These positions indicate the limits of operation. So don't use too much force. 3. In order to prevent dust from entering, when the module is not used, the sealing cap that was originally installed on the corresponding module mounting seat should be placed. When cleaning all kinds of glass parts, it is strictly forbidden to rub with your hand or handkerchief. You can't use your mouth to blow. You must first blow off the surface dust with a special rubber ball, and then wipe it gently with special lens paper. To remove fingerprints or oil stains, wipe with a small amount of ether (70%) and alcohol mixed solution on a special lens tissue. Be careful not to bring these chemicals close to open flames and possible sparks, such as electronic equipment for switching operations. It can only be used in a well ventilated room. 4. If other parts of the microscope other than the glass parts are dirty, wipe them off with a clean cloth. If it is too dirty, do not use organic solvents to wipe. Instead, use a soft, lint-free cloth dampened with a small amount of neutral detergent. 5. Do not disassemble any part of the microscope. This can cause dysfunction or performance degradation. 6. When not using the microscope, be sure to set the main switch to “0†(off). After the lamp chamber is completely cooled, it is covered with the supplied dust cover before storage. 7. The microscope should be placed in a room that is dry and ventilated, with less dust and no corrosive atmosphere in Egypt. The relative humidity in the room should be less than 70%. Pay attention to proper ventilation. However, at the same time, the instrument should not be exposed to direct sunlight for a long time. If the indoor temperature is too low, the grease in the mechanical part is easily frozen, making operation difficult. Place a protective cover on the microscope objective and eyepiece device to prevent dust from entering the lens body. It is best to place anti-fungal agents around the instrument or inside the cavity, such as formaldehyde B-naphthol, thymol and other chronic volatile drugs. 8. The hands and samples should be clean during operation. It is absolutely not allowed to observe the samples that are not dried by the river etchant under the microscope to avoid corroding the optical components such as the objective lens. Focus on the operation, the transformer should be passed when the power is turned on, and it must be light, steady and careful when loading or unloading or replacing the lens. 9. The microscope is a delicate and expensive optical instrument that requires very careful use and proper storage. Keep it dry and clean. Window-Frame Transparent Dressing Window-Frame Transparent Dressing,Oem Shear Transparent Dressing,Custom Transparent Dressing,Waterproof Transparent Dressing Zhende Medical Co.,Ltd , https://www.zhendemedicals.com
1. The microscope is a precision instrument. Be careful when handling it and avoid sudden and severe vibrations. Do not use the instrument in the following situations. Near the air intake and exhaust holes of equipment such as air conditioners. Close to places where abnormal noise equipment is generated.